Volume 7, Issue 4, July 2018, Page: 115-125
Anti-Flammable Properties of Cotton Fabrics Using Eco Friendly Inorganic Materials by Layering Self-Assisted Processing
Sechin Chang, United States Department of Agriculture, Agricultural Research Service - Southern Regional Research Center, New Orleans, USA
Brian Condon, United States Department of Agriculture, Agricultural Research Service - Southern Regional Research Center, New Orleans, USA
Elena Graves, United States Department of Agriculture, Agricultural Research Service - Southern Regional Research Center, New Orleans, USA
Jade Smith, United States Department of Agriculture, Agricultural Research Service - Southern Regional Research Center, New Orleans, USA
Received: Apr. 20, 2018;       Accepted: May 5, 2018;       Published: May 22, 2018
DOI: 10.11648/j.ijmsa.20180704.11      View  290      Downloads  23
Abstract
A flame retardant surface has been prepared by the layer-by layer assemblies of branched polyethylenimine (BPEI), kaolin, urea, and diammonium phosphate (DAP) on cotton fabrics. Four different kinds of cotton fabrics (print cloth, mercerized print cloth, mercerized twill, and fleece) were prepared using solutions of BPEI, urea, DAP, and kaolin. Layer-by-layer assemblies for flame retardant properties were applied by the pad-dry-cure method and each coating formula was rotated for 10, 20, 30, or 40 bilayers. To assess the effectiveness to resist flame propagation on treated fabrics of different constructions the vertical flammability test (ASTM D 6413-11) was used. In most cases char lengths of fabrics that passed the vertical flammability tests were less than 50% of the original length and after-flame and after-glow times were less than one second. Thermogravimetric analysis (TGA) and limiting oxygen indices (LOI, ASTM D 2863-09) were also used to test for flame retardancy. All untreated fabrics showed LOI values of about 19-21% oxygen in nitrogen. LOI values for the four types of treated fabrics were greater than 35% when add-on wt% values were between 11.1 – 18.6 wt %. In addition, structural characterizations of treated fabrics were studied by SEM methods.
Keywords
Cotton Fabric, Flame Retardant, Layering, Flammability Test
To cite this article
Sechin Chang, Brian Condon, Elena Graves, Jade Smith, Anti-Flammable Properties of Cotton Fabrics Using Eco Friendly Inorganic Materials by Layering Self-Assisted Processing, International Journal of Materials Science and Applications. Vol. 7, No. 4, 2018, pp. 115-125. doi: 10.11648/j.ijmsa.20180704.11
Copyright
Copyright © 2018 Authors retain the copyright of this article.
This article is an open access article distributed under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Reference
[1]
P. Wakelyn, N. Bertoniere, A. French, et al. Cotton Fibers. In: M. Lewin, Ed., Handbook of Fiber Chemistry, 3rd ed., CRC Press, Boca Raton, FL, USA, pp. 521-666, 2006.
[2]
M. Alaee, P. Arias, A. Sjödin, and Å. Bergman, “An overview of commercially used brominated flame retardants, their applications, their use patterns in different countries/regions and possible modes of release”, Environmental International, vol. 29, no. 6, pp. 683-689, 2003.
[3]
S. Bourbigot, Flame retardancy of textiles: new approaches. In: Horrocks, A. R. and Price, D., Ed., Advances in Fire Retardant Materials, Woodhead Publishing, Cambridge, UK, pp. 9−40, 2009.
[4]
A. R. Horrocks, “Flame retardant challenges for textiles and fibres: New chemistry versus innovatory solutions”, Polymer Degradation and Stability, vol. 96, no. 3, pp. 377-392, 2011.
[5]
A. R. Horrocks, B. K. Kandola, P. J. Davies, S. Zhang, and S. A. Padbury, “Developments in flame retardant textiles – a review”, Polymer Degradation and Stability, vol. 88, no. 1, pp. 3-12, 2005.
[6]
E. D. Weil and S. V. Levchik, “Flame Retardants in Commercial Use or Development for Textiles”, Journal of Fire Science, vol. 26, no. 3, pp. 243-281, 2008.
[7]
J. E. Hendrix, J. E. Bostic, E. S. Olson, and R. H. Barker, “Pyrolysis and combustion of cellulose. I. Effects of triphenyl phosphate in the presence of nitrogenous bases”, Journal of Applied Polymer Science, vol. 14, pp. 1701-1723. 1970.
[8]
W. A. Reeves, R. M. Perkins, B. Piccolo, and G. L. Drake, “some Chemical and Physical Factors Influencing Flame Retardancy”, Textile Research Journal, vol. 40, pp. 223-231, 1970.
[9]
C. Q. Yang, and X. Qiu,” Flame‐retardant finishing of cotton fleece fabric: part I. The use of a hydroxy‐functional organophosphorus oligomer and dimethyloldihydroxylethyleneurea”, Fire and Materials, vol. 31, pp. 67-81, 2007.
[10]
R. Grumping, M. Opel, and M. Petersen, “Brominated Dioxins and Brominated Flame Retardants in Irish Cow’s Milk”, Organohalogen Compounds, vol. 69, pp. 912 – 915, 2007.
[11]
K. Kishore, and K. Mohandas, “Action of phosphorus compounds on fire‐retardancy of cellulosic materials: A review”, Fire and Materials, vol. 6, pp. 54-58, 1982.
[12]
R. Hidersinn, Fire Retardancy. In: Bikales, N. M. and Mark, H. F., Ed., Encyclopedia of Polymer Science and Technology, John Wiley & Sons, Inc., New York, pp. 270, 1977.
[13]
K. Ariga, J. P. Hill, and Q. Ji, “Layer-by-layer assembly as a versatile bottom-up nanofabrication technique for exploratory research and realistic application”, Physical Chemistry Chemical Physics, vol. 9, no. 19, pp. 2319-2340, 2007.
[14]
G. Decher, “Fuzzy nanoassemblies: toward layered polymeric multicomposites”, Science, vol. 227, no. 5330, pp. 1232-1237, 1997.
[15]
G. Decher, and J. D. Hong, “Buildup of Ultrathin Multilayer Films by a Self-Assembly Process: II. Consecutive Adsorption of Anionic and Cationic Bipolar Amphiphiles and Polyelectrolytes on Charged Surfaces,” Bunsen-Gesellschaft fur Physikalische Chemie, vol. 95, no. 11, pp. 1430-1434, 1991.
[16]
G. Decher, J. D. Hong, and J. Schmitt, “Buildup of ultrathin multilayer films by a self-assembly process. III. Consecutively alternating adsorption of anionic and cationic polyelectrolytes on charged surfaces”, Thin Solid Films, vol. 211, Part 2, pp. 831-835, 1992.
[17]
Y. Lvov, G. Decher, and H. Moehwald, “Assembly, structural characterization and thermal behaviour of layer-by-layer deposited ultrathin films”, Langmuir, vol. 9, no. 2, pp. 481-486, 1993.
[18]
K. Ariga, Y. Lvov, and T. Kunitake, “Assembling Alternate Dye−Polyion Molecular Films by Electrostatic Layer-by-Layer Adsorption”, Journal of the American Chemical Society, vol. 119, no. 9, pp. 2224-2231, 1997.
[19]
W. Chen, and T. J. McCarthy, “Layer-by-Layer Deposition:  A Tool for Polymer Surface Modification”, Macromolecules, vol. 30, no. 1, pp. 78-86, 1997.
[20]
S. T. Dubas, L. Limsavarn, C. Iamsamai, and P. Potiyaraj, “Assembly of polyelectrolyte multilayers on nylon fibers”, Journal of Applied Polymer Science, vol. 101, no. 5, pp. 3286-3290, 2006.
[21]
P. T. Hammond, “Recent explorations in electrostatic multilayer thin film assembly”, Current Opinion in Colloid & Interface Science, vol. 4, no. 6, pp. 430-442, 1999.
[22]
P. T. Hammond, “Form and function in multilayer assembly: New applications at the nanoscale”, Advanced Materials, vol. 16, no. 15, pp. 1271-1293, 2004.
[23]
P. T. Hammond, and G. M. Whitesides, “Formation of Polymer Microstructures by Selective Deposition of Polyion Multilayers Using Patterned Self-Assembled Monolayers as a Template”, Macromolecules, vol. 28, no. 22, pp. 7569-7571, 1995.
[24]
M. Schonhoff, “Self-assembled polyelectrolyte multilayers”, Current Opinion in Colloid & Interface Science, vol. 8, no. 1, pp. 86-95, 2003.
[25]
Q. Wang, and P. Hauser, “New characterization of layer-by-layer self-assembly deposition of polyelectrolytes on cotton fabric”, Cellulose, vol. 16, no. 6, pp. 1123-1131, 2009.
[26]
X. Zhang, H. Chen, and H. Zhang, “Layer-by-layer assembly: From conventional to unconventional methods”, Chemical Communication, vol. 14, pp. 1395-1405, 2007.
[27]
Y.-C. Li, S. Mannen, A. Morgan, S. Chang, Y. H. Yang, B. Condon, and J. Grunlan, “Intumescent all-polymer multilayer nanocoating capable of extinguishing flame on fabric”, Advanced Materials, vol. 23, no. 34, pp. 3926-3931, 2011.
[28]
Y.-C. Li, S. Mannen, J. Schultz, and J. Grunlan, “Growth and fire protection behavior of POSS-based multilayer thin films”, Journal of Material Chemistry, vol. 21, no. 9, pp. 3060-3069, 2011.
[29]
Y.-C. Li, J. Schultz, S. Mannen, C. Delhom, B. Condon, S. Chang, M. Zammarano, and J. Grunlan, “Flame retardant behavior of polyelectrolyte-clay thin film assemblies on cotton fabric”, ACS Nano, vol. 4, no. 6, pp. 3325-3337, 2010.
[30]
Y. Chen, A. Frendi, S. S. Tewari, and M. Sibulkin, “Combustion properties of pure and fire-retarded cellulose”, Combustion and Flame, vol. 84, pp. 121-140, 1991.
[31]
P. Bajaj, Heat and flame protection. In: A. R. Horrocks, and S. C. Anand,, Eds., Handbook of Technical Textiles, Woodhead Publishing and CRC Press, Boca Raton, FL, USA, pp. 223-263, 2000.
[32]
D. Purser, and A. R. Horrocks, Toxicity of fire retardants in relation to life, safety and environmental hazards and Textiles. In: A. R. Horrocks, and D. Price, Eds., Fire Retardant Materials, CRC Press, Boca Raton, FL, USA, pp. 62-181, 2001.
[33]
J. W. Lyons, The Chemistry and Uses of Fire Retardants. Wiley, Hoboken, NJ, USA, (1970).
[34]
T.-M. Nguyen, S. Chang, B. Condon, R. Slopek, E. Graves, and M. Yoshioka-Tarver, “Structural effect of phosphoramidate derivatives on the thermal and flame retardant behaviors of treated cotton cellulose” Industrial & Engineering Chemistry Research, vol. 52, pp. 4715-4724, 2013.
[35]
A. A. Faroq, D. Price, G. J. Milnes, and A. R. Horrocks, “Thermogravimetric analysis study of the mechanism of pyrolysis of untreated and flame retardant treated cotton fabrics under a continuous flow of nitrogen”, Polymer Degradation and Stability, vol. 44, pp. 323-333, 1994.
[36]
T.-M. Nguyen, S. Chang, B. Condon, and R. Slopek, “Synthesis of a novel flame retardant containing phosphorus-nitrogen and its comparison for cotton fabric”, Fibers and Polymers, vol. 13, pp. 963-970, 2012.